IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Fast Ethernet
IEEE 802.3ab 1000Base-TX
IEEE 802.3z Gigabit Ethernet Fiber
IEEE 802.3x Flow Control and Back-pressure
IEEE 802.1p class of service
IEEE 802.1Q VLAN
IEEE 802.1D-2004 Rapid Spanning Tree Protocol (RSTP)
IEEE 802.1s Multiple Spanning Tree Protocol (MSTP)
IEEE802.3ad LACP
IEEE802.1X Port based Network Access Control
IEEE802.1AB Link Layer Discovery Protocol
IEEE 1588v1 Precision Time Protocol (PTP)
|
|
性能
|
|
|
|
10M以太網14,880pps, 100M以太網148,800pps, 千兆以太網1,488,100
|
|
|
|
|
|
|
|
|
|
|
|
網管
|
|
Cisco-Like CLI, JetView, Web, HTTPS, 備份/還原, DHCP Client, 熱重啟, 恢復默認設置, Admin password, 端口速率/雙工控制,狀態顯示, 數據統計, MAC地址列表顯示, 靜態MAC, Aging time, 啟動/關閉巨幀(Jumbo Frame)支持
|
|
|
鏈路層發現協議用于記錄相鄰網絡設備的拓撲連接和管理信息
|
|
|
|
|
|
|
MIB-II, Bridge MIB, VLAN MIB, SNMP MIB, RMON, Private MIB
|
|
|
靜態聚合和802.3ad LACP動態聚合, 最高6個聚合組,每個聚合組最多包含8個端口
|
|
|
IEEE802.1Q VLAN, GVRP. 最多255個VLAN組
|
|
|
可將客戶端的隔離VLAN/聯盟VLAN設置為僅能與主要VLAN的Promiscuous混雜端口通訊
|
|
|
|
|
每個端口8個優先級,支持IEEE802.1p COS 和Layer 3 TOS/DiffServ
|
|
|
支持IGMP Snooping V1/V2/V3 用于多播過濾和IGMP Query
|
|
|
|
|
入棧過濾支持廣播,多播,未知封包或所有類型的封包(64kbps)
|
|
|
|
|
|
|
|
|
|
|
|
|
可使用Radius賬號/密碼登入,可與Radius服務器做認證
|
|
|
阻止/允許ACL訪問 (IP/MAC,TCP/UDP port)
|
|
|
|
|
|
|
|
|
|
|
端口電源斷連,DI狀態,DO狀態,環網故障,登錄失敗,時鐘同步失敗,Super Ring結構變化
|
|
網絡冗余
|
|
IEEE 802.1s MSTP, MSTP Instance可與VLAN整合
|
|
|
IEEE802.1D-2004 RSTP向下兼容傳統STP和IEEE802.1w
|
|
|
新一代Korenix冗余環網技術, 包括 Rapid Super Ring, Rapid Dual Homing, TrunkRing, MultiRing, 向下兼容第一代Super Ring
|
|
|
|
|
|
|
JetNet 5628G支持在單機上創建12個百兆環網和2個千兆環網
|
|
|
|
界面 |
|
10/100/1000Base-TX: 4個RJ-45,SFP combo可選端口
1000Base-X: 4個SFP支持熱插拔
|
|
|
JNM5-8TX: 8 個10/100Base-TX端口,自適應MDI/MDI-X, 自動協商
JNM5-4TX/4SFP: 4個10/100Base-TX 端口加4個100Base-FX SFP插槽
JNM5-2SFP/4MSC: 2個100Base-FX SFP插槽加4個100Base-FX多模光口
JNM5-2SFP/4SSC: 2個100Base-FX SFP插槽加4個100Base-FX單模光口
(操作溫度高于55°C時,請使用寬溫(-40~85°C)版本SFP光纖收發器)
|
|
|
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable (100m)
100 Base-TX: 2/4-pair UTP/STP Cat. 5 cable (100m)
1000 Base-T: 4-pair UTP/STP Cat. 5 cable (100m)
|
|
|
JetNet 5628G:
AC/HDC Power 1/2(綠燈亮), LDC Power 1/2 (綠燈亮),
RDY(Ready) (綠燈亮), Digital Input 1/2 (綠燈亮), Ringmaster(綠燈亮),
Digital Output 1/2(紅燈亮), 環網故障(紅燈亮)
JetNet 5628G-R:
系統: PWR 1/2 (綠燈亮); DO 1(Red);
R.S. (綠燈亮: 環網狀態正常; 綠燈閃爍: 設定不正確;
琥珀燈亮: 環網狀態不正常; 琥珀燈閃爍: 偵測到某一個環網端口不正常)
端口 1-28: 已聯機/傳輸中 (綠燈亮/綠燈閃爍)
|
|
|
快速以太網模塊: Link/Activity (綠燈亮/綠燈閃爍)
千兆Copper/SFP: Link/Activity (綠燈亮/綠燈閃爍)
|
|
|
DB9接頭, Pin3: TxD, Pin2: RxD, Pin5:GND
|
|
|
JetNet 5628G: 1個標準三相AC插頭 +4 pin LDC電源接線槽
JetNet 5628G-2AC: 2個標準三相AC插頭
JetNet 5628G-R: 6 pin高電壓電源接線槽
JetNet 5628G-2HDC: 2個3 pin HDC電源接線槽
|
|
|
2 路 Digital Input (僅JetNet 5628G/5628G-2AC/5628G-2HDC提供)
Logic Low (0): 0-10VDC/Logic High(1): 11-30VDC
|
|
|
JetNet 5628G/5628G-2AC/5628G-2HDC支持2路報警
JetNet 5628G-R支持1路報警
報警規格為1A@24V
|
|
電源要求 |
|
AC: 85-264VAC
HDC (高壓DC輸入): 88-370VDC
LDC (低壓DC輸入): 24/48VDC
|
|
|
|
機械規格 |
|
19英寸1U機架安裝,JetNet 5628G-R采后出線設計,以太網口連接端口在交換機后方
|
|
|
|
|
44mm(H) x 431mm (W) x 375mm (D)
|
|
|
|
工作環境 |
|
|
|
|
|
|
|
|
通過認證 |
|
|
|
FCC Class A, IEC/EN 61000-6-2, CE/EN55022. Class A
|
|
|
EN61000-4-2(ESD), EN61000-4-3(RS),
EN61000-4-4(EFT), EN61000-4-5(Surge),
EN61000-4-6(CS), EN61000-4-8(RF Magnetic),
EN61000-10(Damped oscillator),
EN61000-4-11(Voltage Dips),
EN61000-4-16(Conducted command disturbances),
EN61000-4-17(Ripper on DC power),
EN61000-4-18(Damped oscillatory wave),
EN61000-4-29(Voltage Dips)
IEEE 1613.cl.5.3 Voltage Dips, IEEE 1613 cl.6.3 Impulse Voltage, IEEE 1613 cl.6.2 High Voltage Test
|
|
|
NEMA TS-1/TS-2, EN50121-1, EN50121-4 |
|
|
IEC 61850-3 Clause 5.5, IEC 60870-2-2 table 3
|
|
|
IEC 61850-3 Clause 5.5, IEC 60870-2-2 table 3
|
|
|
IEC 61850-3 Clause 5.5, IEC 60870-2-2 table 3
|
|
|
可達200,000小時, MIL-HDBK-217F GB標準 |
|
|
|